搜索
Products
1/1
Number of views:
1000

Viral transport medium tube with swab

This product is a disposable product, so it is forbidden to reuse. After use, it should be treated as medical waste.
Retail price
0.0
Yuan
Market price
0.0
Yuan
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
Product Details
Product Name Viral transport medium tube with swab
Model/Type 1 test / box, 20 tests / box, 30 tests / box, 50 tests / box, 100 tests / box
Intended Use The product is intended is used for collection, transportation and storage of samples(viruses, chlamydiae, mycoplasma and ureaplasma).
Indication Used for collection, storage and transportation of viruses, chlamydiae, mycoplasma and ureaplasma.
Contraindication The product is strictly prohibited for the sampling of bacterial samples, and the preservative liquid itself contains antibiotics which inhibit the bacteria.
Test population Applicable for all population necessary for swabbing
Intended users Qualified doctors, nurses for specimen collection in a medical laboratory or hospital
Component It is usually composed of swabs and / or cups and tubes containing preservative fluid.
Scope of application It is used for collection, transportation and storage of samples.
Precautions/cautions 1.After sampling, the disposable sampler should be inspected as soon as possible, and transported immediately at low temperature of 2-8 degrees. The samples collected can be stored for 2-8 hours at a low temperature for 48 hours. The long-term storage should be kept at low temperature below -20 C, and stored at -70 C or -196 C.
2. the product is strictly prohibited for the sampling of bacterial samples, and the preservative liquid itself contains antibiotics which inhibit the bacteria.
3. prohibit direct contact with the patients being collected, and remove the wet swabs before sampling the patients.
4. sampling should be done strictly according to the sampling procedure, so that the sampling location is accurate and the sampling intensity is uniform. Otherwise, the quality of sample collection will be affected.
5. the product should not be used after the expiration date or the product package is damaged.
Warning
  1. This product is a disposable product, so it is forbidden to reuse. After use, it should be treated as medical waste;  
  2. Before use, please pay attention to whether the packaging and products are damaged or have other obvious defects. Please check whether the product is within the validity period. If it is beyond the validity period, please do not use it.  
3. Please read the relevant instructions carefully before use, and be familiar with the instructions and operation methods of the product.  
Instruction for use 1.Sterilization of the sampling tube and swab can be done before the medical institution or the user is used.
2.Annotate the relevant sample information on the sampling tube and inject an appropriate amount of sample solution.
3.According to different sampling requirements, sample swabs were sampled at the corresponding locations, holding the handle gently inserting the swab into the sampling area, gently rotating the swab 3-5 times, and then slowly removing it.
4.The sample is put into the sampling tube, and the sample swab is broken out of the sampling tube, then the tube cover is tightened, and the sample is sealed to complete the sampling.
5.The newly collected clinical specimens should be transported to the laboratory within 48 hours at 4℃, and can not be sent to the laboratory for 48 hours. They should be kept at -70℃ or below. Specimens sent to the laboratory should be inoculated and separated as soon as possible, and can be stored at 4℃for 48 hours. If the inoculum is not inoculated, it should be kept at -70 ℃ or below.
6.The conventional sampling methods are as follows:
A) nasal swab: gently wipe the swab head into the nasal passages of the nasal passages, and then slowly exit after stopping for a moment. Wipe the other nostrils with another swab, immerse the swab head in the sample, and discard the tail.
B) pharyngeal swabs: wipe the bilateral pharyngeal tonsils and the posterior pharyngeal wall with swabs, immerse the swab head in the sampling fluid, and discard the tail.
C) gargle: gargle with 10mL normal saline, rinse the head back, make the "Oh" sound, let the saline rotate in the pharynx, and collect the lotion with the 50mL empty sampling tube.
D) nasal lotion: the patient took his posture and his head was slightly backward, injecting 50mL normal saline into the nostril by pipette. He told the patient to simultaneously send K tone to close the pharyngeal cavity, then let the patient lower his head and let out the normal saline, collect the lotion with 50mL empty sampling tube, and repeat the process to wash the two nostrils.
E) nasopharyngeal aspirates: tracheal and bronchial secretions are often collected by this method. Mucus is extracted from the nasopharynx with a collector connected to a negative pressure pump. First, the collector head is inserted into the nasal cavity, and the negative pressure is turned on. The head of the collector is collected and slowly pushed out. Collecting mucus and washing the collector with liquid 5mL for three times.
F) autopsy specimens: autopsy tissue specimens were collected and samples were separated when necessary. Specimens were autopsy tissue.
G) samples of mycoplasma, chlamydia and Ureaplasma samples: male: use sterile cotton swabs to rotate around the urethra about
  2cm for a few seconds. Female: remove the mucus from the cervical mucus and insert the 1-2cm into the cervical canal with sterile swab.
a
Shelf Life 18 months
Duration Single-use only
Contraindication The product is strictly prohibited for the sampling of bacterial samples, and the preservative liquid itself contains antibiotics which inhibit the bacteria.
Warning 1.This product is a disposable product, so it is forbidden to reuse. After use, it should be treated as medical waste;  
2.Before use, please pay attention to whether the packaging and products are damaged or have other obvious defects. Please check whether the product is within the validity period. If it is beyond the validity period, please do not use it.  
3.Please read the relevant instructions carefully before use, and be familiar with the instructions and operation methods of the product.  
Storage condition Store at ambient temperature and store in dry and ventilated places. Be careful of damp. Do not store with poisonous or special smell. Avoid direct contact with fire sources and inflammable and corrosive substances.
a Company:Jiangsu Huaxia Ruitai Plastic Industry Co. Ltd.
Address:Modem technology industry Zone, Jiangyan
a Company: Wellkang Ltd
Address: 16 Castle Street, Dover, CT16 1PW, England, UK
Tel:+44(20)3287 6300,30869438
Fax: +44(20)76811874
E-mail:AuthRep@CE-marking,eu 

 

We could not find any corresponding parameters, please add them to the properties table
Previous
Next

Feedback of customer

Username used for comment:
产品表单
Description:

Related Products

  • Mobile phone detection door
    Mobile phone detection door
    The infrared body temperature screener independently developed and designed by Yongjian Safety: Using imported long-distance infrared temperature sensing probes, when personnel pass the equipment, they will first perform infrared human body temperature measurement, sound and light alarms, voice prompts for abnormal body temperature, "please review body temperature", and pedestrian measurement After warming up, you can reach under the disinfection machine, and then automatically sense the dripping disinfectant, so as to achieve the disinfection effect, avoid continuous contact and spread of the virus in your hands, thereby effectively preventing large-scale disease transmission;
  • conveyor
    conveyor
    All conveyor belts must be connected into a ring before they can be used. Therefore, the quality of the conveyor belt joints directly affects the service life of the conveyor belt and whether the conveyor belt line runs smoothly. Commonly used methods for conveyor belt joints include mechanical joints, cold-bonded joints, and heat-cured joints.
  • Electromagnetic curtain
    Electromagnetic curtain
    The principle of the security screening device is to display the items in the luggage box on the screen in the form of X-rays in order to identify suspicious items in time and eliminate possible dangers. It should be pointed out that although the X-ray radiation dose in the security inspection machine currently in use is very low, it usually does not affect human health, nor does it generally cause radiation pollution to objects and food. However, the internal radiation of the safety machine is still very large, and it can still cause some harm to the human body. In other words, if people enter the security inspection machine directly, their health will be affected.
  • Protective curtain Protective curtain
    Protective curtain
    Many people are worried that radiation during safety inspections will harm the human body. In fact, there are thick X-ray protective curtains on both sides of the security inspection machine, and there is a layer on each side. Block X-rays, because lead materials are not penetrated by X-ray machines. Moreover, this radiation dose has been tested before leaving the factory, and unqualified products are not allowed to leave the factory.
  • Buckle protective curtain Buckle protective curtain
    Buckle protective curtain
    Many people are worried that radiation during safety inspections will harm the human body. In fact, there are thick X-ray protective curtains on both sides of the security inspection machine, and there is a layer on each side. Block X-rays, because lead materials are not penetrated by X-ray machines. Moreover, this radiation dose has been tested before leaving the factory, and unqualified products are not allowed to leave the factory.
  • Wearing a double-sided lead vest
  • Protective dress (shoulder and waist protection style)
  • Protective skirt
  • Protective dress (shoulder style)
  • Regular protective skirt
  • X-ray protective clothing
    X-ray protective clothing
    Lead clothing is specially designed and made according to the sensitive parts of the human body damaged by radiation. After people use radiation protection equipment, they can effectively protect the body from radiation damage. This function is widely loved by people. Lead clothing is suitable for environments where radiation exists, such as radiology, interventional radiology, cardiovascular treatment rooms, orthopedics, and radiotherapy rooms in hospitals. Medical personnel need to use radiation protection equipment to protect their health and prevent radiation damage when performing radiographic diagnosis and radiological interventional treatment.
  • Lead square scarf
  • Lead collar E model
  • Lead collar D model
  • Lead collar C model
  • Lead collar B model
  • Lead collar C model
  • Lead collar A model
  • Electronic label protection curtain
    Electronic label protection curtain
    The principle of the security screening device is to display the items in the luggage box on the screen in the form of X-rays in order to identify suspicious items in time and eliminate possible dangers. It should be pointed out that although the X-ray radiation dose in the security inspection machine currently in use is very low, it usually does not affect human health, nor does it generally cause radiation pollution to objects and food. However, the internal radiation of the safety machine is still very large, and it can still cause some harm to the human body. In other words, if people enter the security inspection machine directly, their health will be affected.
  • Electromagnetic wave protection curtain
    Electromagnetic wave protection curtain
    The security curtain is one of the main accessories of the security door. Security curtains are now bought in many places, and the prices are also various. There are some from a few hundred to a few thousand yuan, so when you buy, there will be some confusion, expensive, afraid of being fooled; cheap, afraid of poor quality. Everyone will only compare them aimlessly in Netshan.
Yongjian

Service line:

Yongjian

Address:

No. 36, Shifan Road, Muping District, Yantai City, Shandong Province

Yongjian

© Yantai Yongjian Safety Protection Equipment Co., Ltd.       鲁ICP备20027029号       Powered by: 300.cn

© Yantai Yongjian Safety Protection Equipment Co., Ltd.       鲁ICP备20027029号     鲁公网安备 37061202000272号     Powered by:300.cn